HUMIDITY PROGRAMMING AND FAN CYCLING: CANDOR MODELS

MODELS THAT UTILIZE THE FAN CYCLING FOR HUMIDITY CONTROL:

•VT-21TS-2Z: Owner's Manual

•VT-24TS-2Z: Owner's Manual

•VT-ECO28SB-01: Owner's Manual

•VT-28-2Z-SSDST: Owner's Manual

•VT-32SBB: Owner's Manual

•VT-32TS-FE: Owner's Manual

•VT-36: Owner's Manual

•VT-36 TS: Owner's Manual

•VT-46TS-2Z: Owner's Manual

•VT-46-2Z-SBB: Owner's Manual

•VT-46-2Z-SSDST: Owner's Manual

•VT-54TS: Owner's Manual

•VT-100TSSB: Owner's Manual

•VT-122TS-2Z: Owner's Manual

•VT-140TS: Owner's Manual

•VT-140TSBW: Owner's Manual

•VT-140RV-2ZR/VT-140TS-2Z: Owner's Manual

•VT-145TSST-2Z: Owner's Manual

•VT-150-2Z-SSDST: Owner's Manual

•VT-155SBB: Owner's Manual

•VT-155SBW: Owner's Manual

•VT-155VCM-GR: Owner's Manual

•VT-155VCM-C (CEC): Owner's Manual

•VT-165TSRV: Owner's Manual

•EL-7TS BLACK & EL-7TSST: Owner's Manual

•EL-45TS: Owner's Manual

•EL-45BSH: Owner's Manual

•EL-54SBB: Owner's Manual

•EL-54SDTH: Owner's Manual

•EL-100SBB: Owner's Manual

•EL-100TSSD: Owner's Manual

•EL-142SDST: Owner's Manual

•EL-142TSST: Owner's Manual

•EL-155BSH: Owner's Manual

•EL-155SDWS: Owner's Manual

•VT-54TS-SM: Owner's Manual

•VT-BC54TSSM-L: Owner's Manual

•VT-7BMSL-FE: Owner's Manual

•VT-32TSFE-SM: Owner's Manual

•VT-BC32TSSM-L: Owner's Manual

•VT-36TS-SM: Owner's Manual

•VT-100WBC-SM: Owner's Manual

•VT-48TSSM-2Z: Owner's Manual

•VT-21TSP-2Z: Owner's Manual

•VT-12TSMD-2Z: Owner's Manual

•VT-12TSP-2Z: Owner's Manual

•VT-WINEDRAWER: Owner's Manual



****FOR DUAL ZONE UNITS:
If customer's intention for a dual zone unit is to be used  for red wine only, unit's design is built for dual zone application of separate temperatures. The upper and lower zones cannot be set at the same temperature, for optimal performance there will be a 4-8 degree variance between the two zones.


The unit has two operating modes for humidity: DYNAMIC COOLING & SILENT MODES


When the set temperature has been reached and when the unit is on the “OFF CYCLE”, the internal evaporator fan motors will each cycle on 20
seconds and off 20 seconds to circulate air inside the cabinet.


The Dynamic Cooling feature enables the relative humidity inside the unit and the temperature to be distributed evenly around the interior so you can store all your wine under exactly the same excellent conditions. If you would like to use the unit to store wine long term, the dynamic cooling is a must.
This will create a continuous climate in the cabinet which imitates that of a wine cellar. 


In the Dynamic Cooling mode, the interior fan circulates the inside air evenly until the set temperature is reached. Dynamic Cooling is the factory preset mode.
To change to Silent mode, touch and hold the UP key for approximately five seconds. The wine cooler will beep three times to confirm silent mode is on.
To change back to Dynamic Cooling mode, touch and hold the DOWN key for approximately five seconds.
The wine cooler will beep five times to confirm Dynamic Cooling mode is on.


If the user feels noise, the user can select the SILENT mode by pressing and holding the UP
mark for at least 5 seconds.


In order to circulate the air and maintain the set temperature inside the cabinet the inside fans
must cycle on and off when the compressor is off in Dynamic Cooling mode.
The fans will cycle ON and OFF approximately every 20 seconds
This cycle is normal and meant both to circulate the air as well as ensure the continued operational status of the fans.
If the fan stops completely and does not complete this cycle the fan is non-operational.